stago compact max user manual pdf
Fully automated, compact, and designed for clinical settings, the STA Compact Max analyzer offers reliable and efficient blood coagulation testing with advanced features for healthcare professionals.
1.1 Key Features of the STA Compact Max
The STA Compact Max features a fully automated design, 96-sample capacity, and 45-reagent positions, ensuring high-throughput testing. It includes a new graphical user interface, advanced thermal control, and integrated data management. The analyzer supports minimal operator intervention, remote monitoring, and seamless integration with laboratory information systems (LIS). Its compact size and robust design make it ideal for clinical and research settings.
1.2 Intended Use of the Analyzer
The STA Compact Max is designed for clinical and laboratory settings to perform blood coagulation and hemostasis testing. It is intended for healthcare professionals to measure various blood parameters, including clotting times and fibrinogen levels. The analyzer supports routine and specialized testing, enabling accurate diagnosis and monitoring of bleeding and clotting disorders in patient samples.
1.3 Benefits of Using the STA Compact Max
The STA Compact Max offers a fully automated design, reducing manual intervention and increasing efficiency. It provides a wide test menu, high throughput, and advanced user-friendly features. The analyzer ensures precise and reliable results, making it ideal for clinical and laboratory settings. Its compact size and intuitive interface enhance workflow, while integration capabilities improve laboratory productivity and consistency in testing.
System Requirements and Installation
The STA Compact Max requires a stable power supply, compatible operating system, and network connectivity. Installation involves placing the analyzer on a level surface and connecting necessary peripherals, ensuring compliance with local regulations and safety standards for optimal performance and reliability in clinical settings.
2.1 Technical Specifications
The STA Compact Max features 96 sample positions and 45 reagent positions, enabling high-throughput testing with minimal operator intervention. It operates on a stable power supply and includes a user-friendly graphical interface. The analyzer measures 75 cm in height, 65 cm in width, and 60 cm in depth, ensuring a compact footprint for laboratory settings. It supports integration with laboratory information systems for seamless data management.
2.2 Installation Process
The STA Compact Max requires careful unpacking and placement on a stable, flat surface. Connect the power supply and ensure proper grounding. Follow the manual’s instructions for initial setup, including loading cuvette rolls and preparing reagents. Perform a system check and calibration as outlined in the reference manual to ensure optimal functionality before commencing operations.
2.3 Network Integration
The STA Compact Max supports seamless integration with laboratory information systems (LIS) and other devices via standard communication protocols. Ensure network compatibility by configuring IP settings and ports as per the manual. Secure data transmission is enabled through encrypted connections. Refer to the STA Compact Max reference manual for detailed instructions on setting up and troubleshooting network connectivity.
Operating the Analyzer
Operate the STA Compact Max by initializing tests via the touchscreen interface, ensuring automated sample processing and continuous operation for efficient blood coagulation analysis.
3.1 Preparing the Analyzer for Use
Ensure the STA Compact Max is powered on and all components are connected. Load the cuvette roll and prepare reagents, controls, and calibrators as per the user manual. Verify the touchscreen interface for any system messages or alerts. Perform a quick check to ensure all parts are functioning correctly before starting analysis.
3.2 Running Tests and Analyzing Samples
Load samples and reagents into the STA Compact Max. The analyzer automatically processes each sample with minimal intervention. The intuitive interface guides operators through test selection and monitoring. Results are generated quickly and stored securely for easy access, ensuring efficient and reliable blood coagulation testing.
3.3 Advanced Operational Features
The STA Compact Max offers enhanced performance with a graphical user interface for streamlined operation. It supports automated sample processing and advanced data management. The system integrates seamlessly with laboratory information systems, ensuring efficient workflow. Features like continuous loading of samples and reagents minimize downtime, while advanced quality control ensures accurate and consistent test results.
Maintenance and Troubleshooting
Regular maintenance ensures optimal performance. Replace cuvette rolls and washing solution as needed. Refer to the manual for troubleshooting common issues and calibration procedures.
4.1 Routine Maintenance Procedures
Perform daily cleaning of the cuvette area and waste container. Check and refill washing solution as needed. Weekly, inspect reagent expiration dates and printer paper levels. Monthly, clean the instrument’s external surfaces and run diagnostic tests. Regularly update software and follow the manual’s guidelines for optimal performance and longevity of the analyzer.
4.2 Calibration and Quality Control
Calibration ensures accurate test results. Use dedicated calibration kits and follow the manual’s procedures. Perform quality control checks regularly with specific reagents. Automated features simplify calibration processes. Document all activities for traceability. Adhere to the manufacturer’s guidelines to maintain precision and reliability in coagulation testing. Regular quality control ensures compliance with laboratory standards and optimal instrument performance.
4.3 Troubleshooting Common Issues
Common issues include error codes, reagent problems, or sample handling errors; Refer to the manual for specific error code solutions. Check reagent expiration dates and ensure proper sample preparation. Clean or replace faulty components as instructed. Regular maintenance can prevent many issues. Consult the STA Compact Max reference manual for detailed troubleshooting procedures and solutions to ensure optimal performance.
Understanding Test Results
The STA Compact Max delivers precise coagulation test results, including clotting times and factor levels. Results are displayed with normal ranges for easy interpretation and decision-making.
5.1 Interpreting Test Results
The STA Compact Max provides clear and detailed test results, including clotting times, factor levels, and ratios. Results are displayed with reference ranges for easy comparison and clinical decision-making.
Abnormal results are highlighted to ensure quick identification of coagulation disorders. The analyzer also offers interpretive guidance, supporting healthcare professionals in diagnosing and monitoring patients effectively.
5.2 Data Management and Storage
The STA Compact Max features integrated software for efficient data management, storing patient results, test parameters, and quality control data securely. It supports data export via USB or network for external analysis. Results can be saved in various formats, including PDF and CSV, ensuring compatibility with laboratory information systems. The system also offers internal storage for historical data tracking and audit trails.
Error Codes and Solutions
The STA Compact Max displays specific error codes (e.g., E001, E002) for troubleshooting. Solutions include restarting the analyzer, checking reagent levels, or contacting Stago Support.
6.1 Common Error Codes
The STA Compact Max often displays error codes such as E001, E002, and E003, indicating issues like low reagent levels, sensor malfunctions, or communication errors. These codes guide users to specific troubleshooting steps, ensuring quick resolution and minimal downtime. Referencing the user manual is essential for understanding and addressing these codes effectively.
6.2 Resolving Errors
Common errors on the STA Compact Max can often be resolved by restarting the system or checking sensor functionality. For issues like reagent level alerts (E001) or communication faults (E002), refer to the user manual for step-by-step solutions. Cleaning sensors, replenishing reagents, or updating software may also address malfunctions. Always consult the manual for specific troubleshooting guidance.
Accessories and Consumables
Essential accessories for the STA Compact Max include cuvette rolls, reagent packs, and control kits; Regular replacement of these ensures optimal performance and accurate test results.
7.1 Overview of Accessories
The STA Compact Max requires specific accessories like cuvette rolls, reagent packs, and control kits to ensure smooth operation. These items are designed to maintain accuracy and efficiency. Additional accessories include washing solution bottles and calibration tools, all of which are available from Stago or authorized distributors to support optimal analyzer performance and longevity.
7.2 Consumables and Reagents
The STA Compact Max requires specific consumables, including cuvette rolls, washing solution, and reagent packs like STA-Liatest. These items are essential for accurate blood coagulation testing and proper instrument maintenance. Regularly replacing these consumables ensures optimal performance and longevity of the analyzer. Always use Stago-approved products to maintain reliability and compliance with quality standards.
Safety Precautions
Handle biological samples with care and dispose of waste properly. Wear appropriate PPE, including gloves and lab coats, to minimize exposure risks. Ensure compliance with local regulations and guidelines for safe operation.
8.1 Handling Biological Samples
Always wear gloves and lab coats when handling biological samples to prevent exposure. Ensure proper sample preparation and labeling to avoid contamination. After handling, wash hands thoroughly and dispose of waste in designated biohazard containers. Follow local regulations and guidelines for safe biological sample management to maintain a secure working environment.
8.2 Waste Disposal Guidelines
Dispose of biological waste in designated biohazard containers. Ensure all contaminated materials are securely packaged and labeled. Follow local regulations for waste disposal, including autoclaving or incineration. Separate non-hazardous and hazardous waste. Properly decontaminate reusable items before reuse. Maintain records of waste disposal to comply with environmental and safety standards. Always adhere to laboratory safety protocols for waste management.
Compatibility with Laboratory Systems
The STA Compact Max integrates seamlessly with laboratory information systems, enhancing workflow efficiency and ensuring compatibility with other laboratory devices for streamlined operations.
9.1 Integration with Laboratory Information Systems
The STA Compact Max supports seamless integration with laboratory information systems, enabling bidirectional communication for efficient workflow management. It adheres to standard protocols, ensuring compatibility and reducing manual data entry, thus enhancing overall laboratory efficiency and accuracy.
9.2 Compatibility with Other Devices
The STA Compact Max is designed to work seamlessly with other laboratory devices, ensuring flexible integration into existing workflows. Its connectivity options support standardized communication protocols, allowing for efficient data exchange and reducing manual tasks. This compatibility enhances laboratory efficiency and ensures accurate results across connected systems.
References and Further Reading
Refer to the official STA Compact Max user manual, technical guides, and manufacturer support for comprehensive details on operation, troubleshooting, and maintenance procedures.
10.1 Additional Resources
For detailed guidance, refer to the STA Compact Max user manual, technical guides, and manufacturer support materials. Additional resources include instructional PDFs, troubleshooting guides, and updated software manuals available on the official Stago website. These materials provide comprehensive information on operation, maintenance, and advanced features of the analyzer.
10.2 Contact Information for Support
For assistance, contact Stago’s customer support team via email at support@stago.com or call +33 (0)1 43 58 30 00. Visit the official Stago website (https://www.stago.com) for technical support, troubleshooting guides, and user manual downloads. The support team is available to address inquiries, provide maintenance guidance, and resolve operational issues for the STA Compact Max analyzer.
The STA Compact Max analyzer is a valuable tool for efficient and reliable blood coagulation testing, offering advanced features designed to meet healthcare professionals’ needs effectively in clinical settings.
11.1 Summary of Key Points
The STA Compact Max analyzer is a fully automatic, compact device designed for efficient blood coagulation testing in clinical settings. It offers advanced features for healthcare professionals, ensuring accurate and reliable results. The user manual provides comprehensive guidance on installation, operation, and maintenance, making it an essential resource for maximizing the analyzer’s performance and integrating it with laboratory systems seamlessly.
11.2 Final Tips for Effective Use
Regularly perform routine maintenance and calibration as outlined in the manual to ensure optimal performance. Follow safety guidelines when handling biological samples and dispose of waste properly. Leverage the analyzer’s advanced features for efficient testing and integrate it with laboratory systems for streamlined workflows. Refer to the user manual for troubleshooting and error resolution to minimize downtime and maintain accuracy.